{"id":108,"date":"2020-02-14T14:50:03","date_gmt":"2020-02-14T06:50:03","guid":{"rendered":"https:\/\/www.bihec.com\/beam-imaging\/?p=108"},"modified":"2020-02-14T14:50:03","modified_gmt":"2020-02-14T06:50:03","slug":"beam-imaging-ion-gun-systems","status":"publish","type":"post","link":"https:\/\/www.bihec.com\/beam-imaging\/beam-imaging-ion-gun-systems\/","title":{"rendered":"Beam Imaging Ion Gun Systems"},"content":{"rendered":"

Beam Imaging Solutions<\/a> (BIS)<\/strong>\u00a0has two Ion Gun systems to offer. Each Gun includes an ion source assembly, heat sink, acceleration and focusing system, vertical deflection plates, a 6\u2033 long velocity filter and a velocity filter guard ring control unit. Components are assembled in a vacuum housing fitted with a flange for mounting onto the customer\u2019s equipment. The guard ring control unit can be mounted into a standard 19\u2033 rack panel. Custom flanges and additional ports may be ordered if needed. When a beam decelerator is required with the gun, an adapter flange is included (model G-1-D and G-2-D Ion Guns). Beam Imaging<\/a> also offers\u00a0control units (E-series)\u00a0for the above Ion Gun Systems<\/a>. The control units include all power supplies needed to operate the Ion Gun as well as a cooling unit for the ion source and vacuum gauge controls. All Ion Beam Components are also available separately or in complete sets (ion source, heat sink, velocity filter, extraction and focus lens system). These complete sets are referred to as an Ion Beam Kit.<\/p>\n

\"\" \"\"<\/p>\n

Ion Guns Model G-1 and G-1-D (non-bakeable)<\/h3>\n

The model G-1 can be operated in an energy range of 500 eV to 10 keV (with optional 20keV). If an ion beam energy less than 500 eV is required, we recommend using the model G-1-D, which includes the model 400 decelerator and can produce mass selected ion beams with energies as low as 1 eV. The vacuum housing of the model G-1 series is made of a polished stainless steel tube, 6\u2033 in diameter and approximately 19\u2033 long. The length includes the model 500 insulator-mounting flange. The total length of the G-1-D is 23 1\/8\u2033 when used with the model 400 decelerator. Both Ion Gun housings are supplied with a 6\u2033 ID roughing port. The standard exit flange on the models G-1 and G-1-D are an 8\u2033 OD and 6\u2033 ID conflat flange. The model G-1-D, however, has a 2 3\/4\u2033 exit flange when used with the decelerator. Both the model G-1 and G-1-D are good for vacuum use to 10-7\u00a0<\/sup>Torr and are not designed for bakeout.<\/p>\n

Ion Guns Model G-2 and G-2-D (bakeable)<\/h3>\n

The G-2 and G-2-D Ion Guns are both designed to operate in the 500 eV to 10 keV (with optional 20keV) energy range. The G-2-D Ion Gun however, which has the optional model 400 decelerator, can be used down to 1 eV. There are two differences between the G-1 and G-2 series Ion Guns. The G-2 Ion Guns are designed to be bakeable to 200o<\/sup>\u00a0C, for use with ultra-high vacuum (UHV) systems. The magnet coils on the velocity filter are encapsulated in a stainless steel jacket and are liquid cooled, thus allowing for higher currents and magnetic field strength. BIS recommends the CU-1 cooling unit for magnet and ion source cooling. The dimensions of the G-2 and G-2-D are the same as the G-1 and G-1-D respectively. Both the G-2 and G-2-D are designed to be good for a vacuum use to 10-9<\/sup>\u00a0Torr.<\/p>\n

Beam Imaging<\/a>\nBeamImaging<\/a>\nBIS-BOS<\/a>\nIon Gun Systems<\/a>\n\u771f\u7a7a\u7cfb\u7edf<\/a>\n\u771f\u7a7a\u8154<\/a>\n\u79bb\u5b50\u67aa<\/a>\n\u79bb\u5b50\u6e90<\/a><\/div>","protected":false},"excerpt":{"rendered":"

Beam Imaging Solutions (BIS)\u00a0has two Ion Gun systems to offer. Each Gun includes an ion so <\/p>\n","protected":false},"author":19,"featured_media":111,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_vp_format_video_url":"","_vp_image_focal_point":[]},"categories":[1],"tags":[18,3,8,25,20,19,24,22],"yoast_head":"\nBeam Imaging Ion Gun Systems - \u8367\u5149\u5c4f \u79bb\u5b50\u6e90 \u79bb\u5b50\u67aa \u901f\u5ea6\u8fc7\u6ee4\u5668 \u79bb\u5b50\u675f\u51cf\u901f\u5668 \u79bb\u5b50\u675f\u504f\u8f6c\u5668 \u6cd5\u62c9\u7b2c\u676f<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.bihec.com\/beam-imaging\/beam-imaging-ion-gun-systems\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Beam Imaging Ion Gun Systems - \u8367\u5149\u5c4f \u79bb\u5b50\u6e90 \u79bb\u5b50\u67aa \u901f\u5ea6\u8fc7\u6ee4\u5668 \u79bb\u5b50\u675f\u51cf\u901f\u5668 \u79bb\u5b50\u675f\u504f\u8f6c\u5668 \u6cd5\u62c9\u7b2c\u676f\" \/>\n<meta property=\"og:description\" content=\"Beam Imaging Solutions (BIS)\u00a0has two Ion Gun systems to offer. Each Gun includes an ion so\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.bihec.com\/beam-imaging\/beam-imaging-ion-gun-systems\/\" \/>\n<meta property=\"og:site_name\" content=\"\u8367\u5149\u5c4f \u79bb\u5b50\u6e90 \u79bb\u5b50\u67aa \u901f\u5ea6\u8fc7\u6ee4\u5668 \u79bb\u5b50\u675f\u51cf\u901f\u5668 \u79bb\u5b50\u675f\u504f\u8f6c\u5668 \u6cd5\u62c9\u7b2c\u676f\" \/>\n<meta property=\"article:published_time\" content=\"2020-02-14T06:50:03+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.bihec.com\/beam-imaging\/wp-content\/uploads\/sites\/345\/2020\/02\/Ion-Gun-Systems-3.jpg?v=1581662971\" \/>\n\t<meta property=\"og:image:width\" content=\"787\" \/>\n\t<meta property=\"og:image:height\" content=\"578\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u4f5c\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"1010 \u7535\u8bdd\uff1a15821107090\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data2\" content=\"2\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.bihec.com\/beam-imaging\/#website\",\"url\":\"https:\/\/www.bihec.com\/beam-imaging\/\",\"name\":\"\\u8367\\u5149\\u5c4f \\u79bb\\u5b50\\u6e90 \\u79bb\\u5b50\\u67aa \\u901f\\u5ea6\\u8fc7\\u6ee4\\u5668 \\u79bb\\u5b50\\u675f\\u51cf\\u901f\\u5668 \\u79bb\\u5b50\\u675f\\u504f\\u8f6c\\u5668 \\u6cd5\\u62c9\\u7b2c\\u676f\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.bihec.com\/beam-imaging\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"zh-CN\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.bihec.com\/beam-imaging\/beam-imaging-ion-gun-systems\/#primaryimage\",\"inLanguage\":\"zh-CN\",\"url\":\"https:\/\/www.bihec.com\/beam-imaging\/wp-content\/uploads\/sites\/345\/2020\/02\/Ion-Gun-Systems-3.jpg?v=1581662971\",\"contentUrl\":\"https:\/\/www.bihec.com\/beam-imaging\/wp-content\/uploads\/sites\/345\/2020\/02\/Ion-Gun-Systems-3.jpg?v=1581662971\",\"width\":787,\"height\":578},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.bihec.com\/beam-imaging\/beam-imaging-ion-gun-systems\/#webpage\",\"url\":\"https:\/\/www.bihec.com\/beam-imaging\/beam-imaging-ion-gun-systems\/\",\"name\":\"Beam Imaging Ion Gun Systems - \\u8367\\u5149\\u5c4f \\u79bb\\u5b50\\u6e90 \\u79bb\\u5b50\\u67aa \\u901f\\u5ea6\\u8fc7\\u6ee4\\u5668 \\u79bb\\u5b50\\u675f\\u51cf\\u901f\\u5668 \\u79bb\\u5b50\\u675f\\u504f\\u8f6c\\u5668 \\u6cd5\\u62c9\\u7b2c\\u676f\",\"isPartOf\":{\"@id\":\"https:\/\/www.bihec.com\/beam-imaging\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.bihec.com\/beam-imaging\/beam-imaging-ion-gun-systems\/#primaryimage\"},\"datePublished\":\"2020-02-14T06:50:03+00:00\",\"dateModified\":\"2020-02-14T06:50:03+00:00\",\"author\":{\"@id\":\"https:\/\/www.bihec.com\/beam-imaging\/#\/schema\/person\/ac1d93b56c20977cb39b3956205a5ee2\"},\"breadcrumb\":{\"@id\":\"https:\/\/www.bihec.com\/beam-imaging\/beam-imaging-ion-gun-systems\/#breadcrumb\"},\"inLanguage\":\"zh-CN\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.bihec.com\/beam-imaging\/beam-imaging-ion-gun-systems\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.bihec.com\/beam-imaging\/beam-imaging-ion-gun-systems\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\\u9996\\u9875\",\"item\":\"https:\/\/www.bihec.com\/beam-imaging\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Beam Imaging Ion Gun Systems\"}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.bihec.com\/beam-imaging\/#\/schema\/person\/ac1d93b56c20977cb39b3956205a5ee2\",\"name\":\"1010 \\u7535\\u8bdd\\uff1a15821107090\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.bihec.com\/beam-imaging\/#personlogo\",\"inLanguage\":\"zh-CN\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/d04f4a62ca087e01ce5102067d0f0b9e?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/d04f4a62ca087e01ce5102067d0f0b9e?s=96&d=mm&r=g\",\"caption\":\"1010 \\u7535\\u8bdd\\uff1a15821107090\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Beam Imaging Ion Gun Systems - \u8367\u5149\u5c4f \u79bb\u5b50\u6e90 \u79bb\u5b50\u67aa \u901f\u5ea6\u8fc7\u6ee4\u5668 \u79bb\u5b50\u675f\u51cf\u901f\u5668 \u79bb\u5b50\u675f\u504f\u8f6c\u5668 \u6cd5\u62c9\u7b2c\u676f","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.bihec.com\/beam-imaging\/beam-imaging-ion-gun-systems\/","og_locale":"zh_CN","og_type":"article","og_title":"Beam Imaging Ion Gun Systems - \u8367\u5149\u5c4f \u79bb\u5b50\u6e90 \u79bb\u5b50\u67aa \u901f\u5ea6\u8fc7\u6ee4\u5668 \u79bb\u5b50\u675f\u51cf\u901f\u5668 \u79bb\u5b50\u675f\u504f\u8f6c\u5668 \u6cd5\u62c9\u7b2c\u676f","og_description":"Beam Imaging Solutions (BIS)\u00a0has two Ion Gun systems to offer. Each Gun includes an ion so","og_url":"https:\/\/www.bihec.com\/beam-imaging\/beam-imaging-ion-gun-systems\/","og_site_name":"\u8367\u5149\u5c4f \u79bb\u5b50\u6e90 \u79bb\u5b50\u67aa \u901f\u5ea6\u8fc7\u6ee4\u5668 \u79bb\u5b50\u675f\u51cf\u901f\u5668 \u79bb\u5b50\u675f\u504f\u8f6c\u5668 \u6cd5\u62c9\u7b2c\u676f","article_published_time":"2020-02-14T06:50:03+00:00","og_image":[{"width":787,"height":578,"url":"https:\/\/www.bihec.com\/beam-imaging\/wp-content\/uploads\/sites\/345\/2020\/02\/Ion-Gun-Systems-3.jpg?v=1581662971","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"\u4f5c\u8005":"1010 \u7535\u8bdd\uff1a15821107090","\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"2\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebSite","@id":"https:\/\/www.bihec.com\/beam-imaging\/#website","url":"https:\/\/www.bihec.com\/beam-imaging\/","name":"\u8367\u5149\u5c4f \u79bb\u5b50\u6e90 \u79bb\u5b50\u67aa \u901f\u5ea6\u8fc7\u6ee4\u5668 \u79bb\u5b50\u675f\u51cf\u901f\u5668 \u79bb\u5b50\u675f\u504f\u8f6c\u5668 \u6cd5\u62c9\u7b2c\u676f","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.bihec.com\/beam-imaging\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"zh-CN"},{"@type":"ImageObject","@id":"https:\/\/www.bihec.com\/beam-imaging\/beam-imaging-ion-gun-systems\/#primaryimage","inLanguage":"zh-CN","url":"https:\/\/www.bihec.com\/beam-imaging\/wp-content\/uploads\/sites\/345\/2020\/02\/Ion-Gun-Systems-3.jpg?v=1581662971","contentUrl":"https:\/\/www.bihec.com\/beam-imaging\/wp-content\/uploads\/sites\/345\/2020\/02\/Ion-Gun-Systems-3.jpg?v=1581662971","width":787,"height":578},{"@type":"WebPage","@id":"https:\/\/www.bihec.com\/beam-imaging\/beam-imaging-ion-gun-systems\/#webpage","url":"https:\/\/www.bihec.com\/beam-imaging\/beam-imaging-ion-gun-systems\/","name":"Beam Imaging Ion Gun Systems - \u8367\u5149\u5c4f \u79bb\u5b50\u6e90 \u79bb\u5b50\u67aa \u901f\u5ea6\u8fc7\u6ee4\u5668 \u79bb\u5b50\u675f\u51cf\u901f\u5668 \u79bb\u5b50\u675f\u504f\u8f6c\u5668 \u6cd5\u62c9\u7b2c\u676f","isPartOf":{"@id":"https:\/\/www.bihec.com\/beam-imaging\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.bihec.com\/beam-imaging\/beam-imaging-ion-gun-systems\/#primaryimage"},"datePublished":"2020-02-14T06:50:03+00:00","dateModified":"2020-02-14T06:50:03+00:00","author":{"@id":"https:\/\/www.bihec.com\/beam-imaging\/#\/schema\/person\/ac1d93b56c20977cb39b3956205a5ee2"},"breadcrumb":{"@id":"https:\/\/www.bihec.com\/beam-imaging\/beam-imaging-ion-gun-systems\/#breadcrumb"},"inLanguage":"zh-CN","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.bihec.com\/beam-imaging\/beam-imaging-ion-gun-systems\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.bihec.com\/beam-imaging\/beam-imaging-ion-gun-systems\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/www.bihec.com\/beam-imaging\/"},{"@type":"ListItem","position":2,"name":"Beam Imaging Ion Gun Systems"}]},{"@type":"Person","@id":"https:\/\/www.bihec.com\/beam-imaging\/#\/schema\/person\/ac1d93b56c20977cb39b3956205a5ee2","name":"1010 \u7535\u8bdd\uff1a15821107090","image":{"@type":"ImageObject","@id":"https:\/\/www.bihec.com\/beam-imaging\/#personlogo","inLanguage":"zh-CN","url":"https:\/\/secure.gravatar.com\/avatar\/d04f4a62ca087e01ce5102067d0f0b9e?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d04f4a62ca087e01ce5102067d0f0b9e?s=96&d=mm&r=g","caption":"1010 \u7535\u8bdd\uff1a15821107090"}}]}},"_links":{"self":[{"href":"https:\/\/www.bihec.com\/beam-imaging\/wp-json\/wp\/v2\/posts\/108"}],"collection":[{"href":"https:\/\/www.bihec.com\/beam-imaging\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bihec.com\/beam-imaging\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/beam-imaging\/wp-json\/wp\/v2\/users\/19"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/beam-imaging\/wp-json\/wp\/v2\/comments?post=108"}],"version-history":[{"count":1,"href":"https:\/\/www.bihec.com\/beam-imaging\/wp-json\/wp\/v2\/posts\/108\/revisions"}],"predecessor-version":[{"id":112,"href":"https:\/\/www.bihec.com\/beam-imaging\/wp-json\/wp\/v2\/posts\/108\/revisions\/112"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/beam-imaging\/wp-json\/wp\/v2\/media\/111"}],"wp:attachment":[{"href":"https:\/\/www.bihec.com\/beam-imaging\/wp-json\/wp\/v2\/media?parent=108"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bihec.com\/beam-imaging\/wp-json\/wp\/v2\/categories?post=108"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bihec.com\/beam-imaging\/wp-json\/wp\/v2\/tags?post=108"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}